Skip to main content

Power Conditioner

Furman M-8x2 Power Conditioner

The Furman M-8x2 is the most affordable rack-mount power conditioner in Furman's lineup, providing basic surge protection and EMI/RFI filtering across eight rear-panel outlets. It lacks the pull-out rack lights and voltage meters of its siblings, but for budget builds or secondary racks where you just need clean, protected power distribution, it gets the job done at the lowest possible cost. A sensible starting point for any rack build.

Compare

Photos

Manufacturer product photography — the drawn faceplate stays true to panel layout; these show the hardware itself.

Photo: FurmanClick to zoom
Documented outputs
99 destination connections
Documented inputs
1Based on documented inputs
Rack space
1UBuilder checks available rail space
Power draw
UnverifiedPower requirement is not verified in the catalog
Catalog estimate
~$99Use retailer rows for current price and stock

01 · What it does—and what that changes in your rig.

Product overview

Start with the payoff, then work through how it functions, where it fits, and the details that change a real build.

The payoff

Power Conditioner decisions, organized around the whole rig.

The M-8x2 is Furman's entry point into rack power — a 1U conditioner that takes a single NEMA 5-15 feed and distributes it across eight rear-panel outlets with surge protection and EMI/RFI filtering baked in. In an IEM rack or playback rig, its job is straightforward: give every unit in the rack a clean, protected place to plug in without running a daisy-chain of power strips through the back. It won't impress anyone on a spec sheet, but reliable power distribution is the thing you only notice when it's missing.

Documented outputs
99 destination connections
Documented inputs
1Based on documented inputs
Rack space
1UBuilder checks available rail space
Furman product panel1U · Unverified
Function

How it works in the path

At 15 amps across eight outlets, the M-8x2 has enough headroom for a typical IEM or playback rack where most units draw modest power — wireless receivers, a personal mixer, a small switch, maybe a Mac Mini. The shallow 210mm depth fits easily in compact tour-style racks. What you're giving up compared to pricier Furman models is real: there's no front-panel voltmeter to catch a bad venue feed, no pull-out work lights, and no advanced Series Multi-Stage Protection. The filtering is basic. If you're pulling from a sketchy generator or working venues with genuinely dirty power, you'll want something higher in the lineup.

Best fit

Where it earns its place in the rack

The M-8x2 makes the most sense in a secondary or rehearsal rack, a broadcast or streaming cart, or any build where budget discipline matters more than premium filtration — say, a fly-date IEM pack where you're supplementing a known-good house feed. Touring engineers who hit a new building every night and have seen what a voltage sag can do to a show should step up to a Furman with a proper voltmeter at minimum. But for a locked-in corporate residency, a rehearsal studio rack, or a monitor world where another conditioner is already upstream, the M-8x2 earns its place without argument.

In the rack

Details worth deciding before load-in.

  • Put it at the bottom of the rack — it has no front-panel display to read, so prime eye-level real estate is wasted on it; save that space for your wireless or mixer.
  • Count your outlet load before you wire up: eight outlets sounds like plenty until a tech patches in a laptop charger and a phone brick 'just for a second' — label the outlets and assign them at build time.
  • Because there's no voltage meter, carry a cheap plug-in voltage tester or use your phone's audio interface to spot-check the house feed before power-up in unfamiliar venues.
  • At 210mm deep it clears most shallow rack bags with room to spare — if you're building a fly pack around a 16-inch-deep bag rack, confirm your deepest unit, not this one, is the depth constraint.

02 · Know the whole path before you buy.

Signal path

Learn the route as a block diagram: source, product function, transport, and destination. Select any block to see what enters, what changes, and what leaves.

Interactive block diagramAuto-looping · hover, focus, or tap to hold a stage
Port-type signalProduct functionSystem boundary
Follow one signal from source to destination

Each block answers the same three questions: what arrives, what changes here, and what leaves.

01 · Source · selected
01 · Source

1 documented input

nema 5 15

Arrives as
1 documented input
Connector
nema 5 15
Signal
power

03 · What this product asks of the rest of the system.

Compatibility

Treat connector names as the start of the check—not the answer. These are the boundaries that determine a complete working path.

Best fit · Power Conditioner

Use it when 1U and 95.3 mm of depth fit the case.

Plan the companion path

Complete the path with upstream and downstream gear that matches connector, direction, signal type, protocol, and wiring standard.

Connector boundary

Documented connectors: nema 5 15. Match connector, direction, and signal type—not shape alone.

04 · Every connector, grouped by job.

I/O ports

Switch the product view and the documented port inventory updates with it—hardware and data stay side by side.

Every connector, grouped by job.

Switch panels to keep the hardware view and the documented port list in sync.

Front panel
Rear panel
All documented ports for Furman M-8x2 Power Conditioner
PortPanelConnectorDirectionSignalChannels
LINE CORDrearnema 5 15 inputpower—
OUTLET 1rearnema 5 15 outputpower—
OUTLET 2rearnema 5 15 outputpower—
OUTLET 3rearnema 5 15 outputpower—
OUTLET 4rearnema 5 15 outputpower—
OUTLET 5rearnema 5 15 outputpower—
OUTLET 6rearnema 5 15 outputpower—
OUTLET 7rearnema 5 15 outputpower—
OUTLET 8rearnema 5 15 outputpower—
FRONT OUTLETfrontnema 5 15 outputpower—

Showing 10 of 10 documented physical ports.

05 · Compare the decision, not just the price.

Alternatives

The rows are organized around fit, power, I/O, and system role so a cheaper unit cannot hide a more expensive workflow.

Compare
Furman M-8x2 — plain 1U front panel with switched outlet and protection LED
Furman P-1800 PF R — 1U front panel with USB charger, blue voltmeter and 20A outlet
Furman PL-8C — 1U three-quarter view with retractable light knobs and front outlet
Furman PL-Plus DMC — 1U three-quarter view with digital voltmeter/ammeter and front outlet
Fit📐 1U📐 1U📐 1U📐 1U
Power⚡ Unverified⚡ 8W⚡ Unverified⚡ Unverified
Weight⚖️ 4.4 lb⚖️ 13.2 lb⚖️ 11.0 lb⚖️ 11.0 lb
I/O🔌 10🔌 12🔌 11🔌 11
Estimate💵 ~$99💵 ~$599💵 ~$219💵 ~$399
Deep diveCurrent selectionFull comparison →Full comparison →Full comparison →

06 · Resolve the questions that can change the purchase or build plan.

Planning questions

Short, source-backed answers surface rack fit, power, cabling, and connection details before they become surprises.

How will the Furman M-8x2 Power Conditioner affect rack fit and case depth?

It occupies 1U. Its documented depth is 95.3 mm.

How much power does the Furman M-8x2 Power Conditioner draw?

Its power requirement is not yet verified in the catalog.

What connections does the Furman M-8x2 Power Conditioner have?

10 documented physical ports, including LINE CORD, OUTLET 1, OUTLET 2, OUTLET 3, OUTLET 4, OUTLET 5.

07 · See this unit inside a real rack plan.

Builder preview

Placement is only the start. Builder checks space · depth · weight, power headroom, dependencies, and compatible signal paths around this exact catalog item.Open in Builder
M-8x2 Power Conditioner positioned in a rack planA simplified plan shows the unit taking 1 rack units, with its documented connection path continuing to a planned destination.FurmanM-8x2CONNECTED GEARnext signal destination1U · 95.3 mm deep

08 · Related gear, in the order you may need it.

See how other people are using this gear.

Community rigs

Browse all →

Planning guides for power conditioner systems.